LCP E115i 含15%玻璃纤维增强
  • 产 品:LCP E115i 含15%玻璃纤维增强
  • 产 地:泰科纳
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

VECTRA® LKX1387 BK210P BLACK

VECTRA E115i | LCP | Glass Reinforced

Description
VECTRA LCP E115i 15% glass reinforced

Chemical abbreviation according to ISO 1043-1 : LCP
Inherently flame retardant.
FDA compliant

UL-Listing V-0 black at 0.75mm thickness per UL 94 flame testing. 

UL = Underwriters Laboratories (USA)

ISO Data Physical properties Value Unit Test Standard
Phys Density 1460 kg/m³ ISO 1183
Mold shrinkage - parallel -0.2 % ISO 294-4
Mold shrinkage - normal 0.5 % ISO 294-4
Mech Mechanical properties Value Unit Test Standard
Tensile modulus (1mm/min) 14000 MPa ISO 527-2/1A
Tensile stress at break (5mm/min) 175 MPa ISO 527-2/1A
Tensile strain at break (5mm/min) 2.3 % ISO 527-2/1A
Flexural modulus (23℃) 14000 MPa ISO 178
Flexural strength (23℃) 210 MPa ISO 178
Unnotched impact str (Izod) @ 23℃ 101 kJ/m² ISO 180/1U
Notched impact strength (Izod) @ 23℃ 40 kJ/m² ISO 180/1A
Rockwell hardness 43 M-Scale ISO 2039-2
Therm Thermal properties Value Unit Test Standard
Melting temperature (10℃/min) 336 ISO 11357-1,-2,-3
DTUL @ 1.8 MPa 252 ISO 75-1/-2
DTUL @ 0.45 MPa 298 ISO 75-1/-2
Vicat softening temperature B50 (50℃/h 50N) 202 ISO 306
Flammability at thickness h V-0 class UL94
thickness tested (h) 0.75 mm UL94
UL recognition (h) UL - UL94
Elec Electrical properties Value Unit Test Standard
Volume resistivity >1E14 Ohm*m IEC 60093
Surface resistivity >1E15 Ohm IEC 60093
Electric strength 33 kV/mm IEC 60243-1
SpecProd Test specimen production Value Unit Test Standard
Injection molding melt temperature 340 ISO 294
Injection molding mold temperature 100 ISO 294
Injection molding flow front velocity 150 mm/s ISO 294
Injection molding hold pressure 69 MPa ISO 294

Processing
Pre Drying
Necessary low maximum residual moisture content: 0.01%

VECTRA should in principle be predried. Because of the necessary low maximum residual moisture content the use of dry air dryers is recommended. The dew point should be =< - 40℃. The time between drying and processing should be as short as possible.

For subsequent storage of the material in the dryer until processed the temperature does not need to be lowered for grades A, B, C, D and V (<= 24 h).

Drying time (h):6
Drying temperature (℃):150-150