旭化成 南亚 东丽 巴斯夫 罗地亚 普立万 长春

杜邦 泰科纳 三菱工程 GE料 朗盛 RTP 舒尔曼

改性尼龙 改性PBT 代理PTFE聚四氟乙烯粉

塑料种类

通用塑料 PVCGPPSHDPELDPEHIPSSAN

工程塑料 PVDFPSUPPSUPOPPFAPA4TPA9TPA6TPA610PA1010PA12PA11EPSEMAPPOCOCPA46PA6PA6/66PA612PEEKPPEPTFE

热塑弹性体CPETPVSISSBSSBRPBEPOETPX

联系我们

塑胶原料报价
PC DP003EH 含聚四氟乙烯,硅酮,易成型
  • 产 品:PC DP003EH 含聚四氟乙烯,硅酮,易成型
  • 产 地:美国液氮
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

LNP Lubricomp* Polycarbonate Compound
Strong, tough -- and wear-resistant
Polycarbonate-based LNP Lubricomp compounds add wear resistance and lower the friction of polycarbonate by combining it with internal lubricants. Glass and carbon fibers can also be included for improved strength and stiffness.

LNP™ Lubricomp™ Compound PC DP003EH 塑料数据

Also known as:LNP™ Lubricomp™ Compound DL-4530 EM HC
Product reorder name:DP003EH
LNP LUBRICOMP* DP003EH is a compound based on Polycarbonate resin containing PTFE, Silicone. Added features of this material include: Easy Molding.

MECHANICAL Value Unit Standard
Tensile Stress,yield 410 kgf/cm² ASTM D 638
Tensile Stress,break 470 kgf/cm² ASTM D 638
Tensile Stress,yld,Type I,5mm/min 490 kgf/cm² ASTM D 638
Tensile Stress,brk,Type I,5mm/min 430 kgf/cm² ASTM D 638
Tensile Strain,yield 5 % ASTM D 638
Tensile Strain,break 17 % ASTM D 638
Tensile Strain,yld,Type I,5mm/min 5.9 % ASTM D 638
Tensile Strain,brk,Type I,5mm/min 49 % ASTM D 638
Tensile Modulus,50mm/min 20700 kgf/cm² ASTM D 638
Flexural Stress 790 kgf/cm² ASTM D 790
Flexural Modulus 21000 kgf/cm² ASTM D 790
Flexural Modulus,1.3mm/min,50mm span 21400 kgf/cm² ASTM D 790
Tensile Stress,yield,5mm/min 48 MPa ISO 527
Tensile Stress,break,5mm/min 46 MPa ISO 527
Tensile Strain,yield,5mm/min 5.7 % ISO 527
Tensile Strain,break,5mm/min 116 % ISO 527
Tensile Modulus,1mm/min 2010 MPa ISO 527
Flexural Stress 61 MPa ISO 178
Flexural Modulus,2mm/min 1920 MPa ISO 178
IMPACT Value Unit Standard
Izod Impact,unnotched,23℃ 153 cm-kgf/cm ASTM D 4812
Izod Impact,notched,23℃ 48 cm-kgf/cm ASTM D 256
Multiaxial Impact 208 cm-kgf ISO 6603
Instrumented Impact Total Energy,23℃ 302 cm-kgf ASTM D 3763
Izod Impact,unnotched 80*10*4 +23℃ 174 kJ/m² ISO 180/1U
Izod Impact,notched 80*10*4 +23℃ 41 kJ/m² ISO 180/1A
THERMAL Value Unit Standard
HDT,0.45 MPa,3.2mm,unannealed 141 ASTM D 648
HDT,1.82 MPa,3.2mm,unannealed 128 ASTM D 648
CTE,-30℃ to 30℃,flow 7.80E-05 1/℃ ASTM D 696
CTE,-30℃ to 30℃,xflow 7.60E-05 1/℃ ASTM D 696
HDT/Bf,0.45 MPa Flatw 80*10*4 sp=64mm 140 ISO 75/Bf
HDT/Af,1.8 MPa Flatw 80*10*4 sp=64mm 127 ISO 75/Af
PHYSICAL Value Unit Standard
Specific Gravity 1.26 - ASTM D 792
Density 1.26 g/cm³ ASTM D 792
Moisture Absorption,50% RH,24 hrs 0.13 % ASTM D 570
Mold Shrinkage,flow,24 hrs(5) 0.6-0.9 % ASTM D 955
Mold Shrinkage,xflow,24 hrs(5) 0.7-1 % ASTM D 955
Wear Factor Washer 28 10^-10 in^5-min/ft-lb-hr ASTM D 3702 Modified
Wear Factor Ring -1 10^-10 in^5-min/ft-lb-hr ASTM D 3702 Modified
Dynamic COF 0.29 - ASTM D 3702 Modified
Static COF 0.15 - ASTM D 3702 Modified
Moisture Absorption(23℃/50% RH) 0.19 % ISO 62
Source GMD,last updated:2004/09/29
Parameter Injection Molding Value Unit
Drying Temperature 120
Drying Time 4 hrs
Maximum Moisture Content 0.02 %
Melt Temperature 300-315
Front-Zone 3 Temperature 310-320
Middle-Zone 2 Temperature 305-315
Rear-Zone 1 Temperature 295-305
Mold Temperature 80-110
Back Pressure 0.2-0.3 MPa
Screw Speed 30-60 rpm
Source GMD,last updated:2004/09/29

THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES.
Buy SABIC Innovative please contact xiang zhang Engineering plastics

1、Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23℃/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294.
2、Only typical data for selection purposes. Not to be used for part or tool design.
3、This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
4、Internal measurements according to UL standards.
5、Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.

关健字:【LNP™ Lubricomp™ Compound PC DP003EH